Program Overview
Since 2014 Tianhua has supplied Fresenius Kabi — a global leader in lifesaving medicines and technologies — with MedShield® pharmaceutical oxygen absorbers and oxygen indicators protecting fat emulsions and intra/post-operative nutritional fluids, among the most commonly used products in operating rooms and hospital wards worldwide.
Challenge & Protection Requirements
Fat emulsions and amino acid-based nutritional fluids are among the most oxygen-sensitive pharmaceutical products: dissolved oxygen drives lipid peroxidation, protein oxidation, and degradation of active ingredients. The client's "Three Controls" specification demanded simultaneous oxygen, moisture, and compound-stability control — plus a unidirectional, irreversible oxygen indicator that changes color permanently once oxygen drops below the threshold, providing an unambiguous, tamper-evident safety signal.
Solution
The MedShield® absorber — GMP clean room production, FDA DMF Level 3 — reaches ≤ 0.05% O2 within 96 hours and holds below 0.01% long-term. The paired liquid oxygen indicator changes permanently from green to yellow at the anaerobic threshold and withstands 121 °C heat sterilization.
Application Media


Products Used
MedShield® Pharmaceutical Oxygen Absorber
Controls oxygen in the documented fat-emulsion and clinical-nutrition fluid packaging program.
MedShield® Liquid Oxygen Indicator
Provides the documented irreversible Green → Yellow final-state indication.
Deoxygenation Performance: 21% to ≤ 0.05% in 96 Hours
| Time After Sealing | O2 Concentration | Stage | Status |
|---|---|---|---|
| 0 h (initial) | ~21.0% | Ambient air | Packaging sealed |
| 24 h | ~5.0% | Early absorption | Active |
| 48 h | ~0.5% | Approaching target | On track |
| 72 h | ~0.1% | Near-anaerobic | On track |
| 96 h | ≤ 0.05% | Target achieved | Achieved |
| 168 h (7 days) | < 0.01% | Stable maintenance | Long-term protection |
Additional Validation Data
MedShield® Liquid Oxygen Indicator — Irreversible
| Parameter | Specification |
|---|---|
| Color Change | Green → Yellow (unidirectional, irreversible) |
| Response Time | Within 24 hours (23 ± 2 °C) |
| Sterilization Resistance | Withstands heat sterilization at 121 °C |
| Size | 40 × 30 mm |
| Applicable Humidity | RH ≥ 60% |
| Shelf Life | 3 years |
Key Advantages
- Irreversible Indicator — One-way green-to-yellow color change; tamper-evident and reliable.
- Three Controls Achieved — Simultaneous moisture, compound, and oxygen control.
- FDA DMF Level 3 Certified — Meets US FDA pharmaceutical-grade requirements.
- GMP Clean Room Production — Pharmaceutical-grade manufacturing environment.
- Sterilization Compatible — Liquid indicator withstands heat sterilization at 121 °C.